Wiring
your Energizer:
You
can now connect the energizer to the ElectroBraid. Run a length
of copper lead-out wire from the positive terminal on your energizer
to the top strand of Braid. Feed the copper wire into a copper
split-bolt, which is fastened to the strand, making sure the wire
has direct contact with the wires in the Braid.
 |
WARNING:
Never loosen the split-bolt connector without first taking the
tension off the line you want to electrify, first. Use the ratchet
and clamp to release and hold the tension before releasing the
split-bolt.
|
NOTE:
For easier troubleshooting, it is best to use an extra split-bolt
connector for electrical connections. Then if, you need to disconnect
the wiring from a strand you will not have to use the tensioning
device to hold the tension.
NOTE:
Use of cable ties will prevent lead-out wire from breaking due to
vibration.
After
the tension has been taken off the line you are electrifying, feed
the copper wire from the energizer into the Split-Bolt Connector.
While you have the split-bolt connector loose, cut and insert another
piece of insulated copper lead-out wire that will be used to jump
the electricity to the third strand (Note: Skip the second-from-the-top
strand - it will be grounded to the negative terminal on the energizer
or to the ground system). Repeat for the fourth strand (this technique
will allow you to easily disconnect the lower line(s) in case of heavy
accumulation of wet snow which may cause the fence to short). Before
inserting, pre-measure the proper length of the jumper wires and strip
away 1" of insulation so the copper in the lead wire is exposed to
ensure a good connection. After all leads have been connected, re-tighten
the split-bolt, release the ratchet and attach cable ties. Bury all
wiring 8" - 10".
NOTE: We recommend you thread all positive wiring through
a piece of 3/4" conduit (flexible Poly well water pipe) to
avoid abrasion and to prevent shorting between negative and positive
wires. Bury the pipe 8"-10" deep. Strap the ends of the
pipe to the gate posts with the ends turned down to prevent rains
and dirt from filling the pipe.
Call us: 03 8727 6244